Downloads

Pick your product by type
Pick your product by range

Software

RedNet Control 2.0
14/11/2016
Click here for more details:
  • RedNet Control 2.0 Supports:
    • Mac:
      • OS X 10.9 (Mavericks)
      • OS X 10.10 (Yosemite)
      • OS X 10.11 (El Capitan)
      • macOS Sierra
    • Windows:
      • Windows 7 (32/64 bit)
      • Windows 8 (32/64 bit)
      • Windows 10 (32/64 bit)

 Important notes

  • During installation, a dialog can appear from Audinate's "Dante Control and Monitoring Installer" about firewall settings on Windows 8. Please manually confirm your firewall settings allow Dante Control & Monitoring through the firewall.
  • For Brooklyn 1 devices that are currently on Firmware Version 3.4, please follow these steps to upgrade your device: https://us.focusrite.com/downloads/rednet-34-to-37-firmware-update-redne...

 Known Issues

  • RedNet AM2: When a signal is present on Channel 2 and not on Channel 1, RedNet Control will not show signal metering on Channel 2.
  • Defaults message from Pro Tools does not clear linked channels on RedNet 4.
RedNet Control 1.10
07/07/2016
Click here for more details:

Important Information

RedNet 1, 2, 3, 4 and 5 devices which are currently running Dante software version 3.4.x are not discovered in RedNet Control 1.10. These devices must be updated to Dante software version 3.7 first. Please download the zip file below and follow the included instructions to perform this update.

Note: See 'RedNet Control 1.10 Download' section for operating system compatibility. 

New Features in RedNet Control 1.10

  • RedNet A8R Support
  • RedNet A16R Support
  • RedNet PCIeR Support
  • Updated Brooklyn Firmware.
    • Brooklyn 1: SW 3.7.2.1/ FW 3.3.8.13
    • Brooklyn 2:  SW 3.10.0.19/ FW 4.0.2.1
    • RedNet Firmware: v1425
  • Updated Ultimo Firmware.
    • Ultimo: SW 3.10.1.12/ FW 1.0.0.2
      • (Non-Automatic Firmware Update - See Important Notes)
  • Updated PCIe/PCIeR Firmware
    • PCIe/ PCIeR: SW 3.10.0.9/ FW 4.2.0.4
  • Dante Device Lockout
    • Locks out the following functions from RedNet Control for devices on SW 3.10 and above:
      • Firmware Updates (Devices need to be unlocked for Firmware Updates)
      • Sample Rate Changes
      • Preferred Master Changes
      • Clocking Changes
    • When Dante Device Lockout is set, a red padlock is displayed on the device plugin in RedNet Control 

 

RedNet Control 1.10 Download

  • RedNet Control 1.10 Supports:
    • Mac:
      • OS X 10.9.x (Mavericks)
      • OS X 10.10.x (Yosemite)
      • OS X 10.11.x (El Capitan)
    • Windows:
      • Windows 7 (32/ 64 bit)
      • Windows 8 (32/ 64 bit)
      • Windows 10 (32/ 64 bit)

 

Important notes

  • There is a firmware update available for Ultimo Products (RedNet AM2) which will enable the Audinate 3.10 Firmware which includes Dante Lockout. To access this file, see instructions below and update using Dante Firmware Update Manager:
    • Retrieve "ult-01-002-3.10.1.12.dnt" from the RedNet Control 1.10 installation.
      • Mac: Applications/RedNet Control.app (Right Click "Show Package Contents") Contents/Resources/Firmware/Ultimo/"ult-01-002-3.10.1.12.dnt"
      • Windows: Program Files/Focusrite/RedNet Control/Firmware/Ultimo/"ult-01-002-3.10.1.12.dnt"
    • Dante Firmware Update Manager can be downloaded here: https://www.audinate.com/products/firmware-update-manager
  • RedNet AM2: When changing attenuation levels in software, please remove headphones and turn the headphone level down.
  • The RedNet PCIe driver is only compatible with the latest firmware.
  • It is important to note that installing new firmware on to any RedNet Unit can take some time, please DO NOT turn the unit off or interrupt the firmware installation - Units will be unresponsive  during this process.
  • During firmware updates, DO NOT add or remove devices on your Dante network.

 

Known Issues

·       RedNet AM2: When a signal is present on Channel 2 and not on Channel 1, RedNet Control will not show signal metering on Channel 2.

·       Defaults message from Pro Tools does not clear linked channels on RedNet 4.

·       It's possible for RedNet Control GUI to display values of 1–7dB for RedNet 4 when controlled via SysEx. The gain on the unit will still be 0dB or 8dB.

·       During installation, a dialog can appear from Audinate's "Dante Control and Monitoring Installer" about firewall settings on Windows 8. Please manually confirm your firewall settings allow Dante Control & Monitoring through the firewall.

·       Windows Only: Long device & channel names in RedNet Control will overflow the text boxes.

·       Windows Only: MIDI settings will only be stored between sessions if running with elevated privileges. 

 

RedNet Control 1.8.3 - Mac OS X 10.8.x Only
07/07/2016
Click here for more details:
Important information: RedNet 1, 2, 3, 4 and 5 devices which are currently running Dante software version 3.4.x are not discovered in RedNet Control 1.8 or 1.9. These devices must be updated to Dante software version 3.7 first. Please download the zip file below and follow the included instructions to perform this update.

RedNet Control 1.8 Release Notes

Note: See 'RedNet Control 1.8 Download' section (below) for operating system compatibility. 

New Features in RedNet Control 1.8

  • RedNet AM2 Support
  • Improved Stability and Responsiveness
  • Improved Network Discovery and Device Identification
  • Improved MIDI Message Handling
  • Improved Responsiveness and Reliability of RedNet 4 and RedNet MP8R Preamp Control
  • Multiple instances of RedNet Control will now stay in sync with gain changes made on other software
  • Global Save and Recall Presets for RedNet 4 and RedNet MP8R
  • PCIe Driver and Firmware Update
    • Driver Version:
      • Mac: 1.7.6.3
      • Windows: 1.7.8.2
    • Firmware Version: 3.7.3.1
    • 176.4kHz addition
    • Static IP addition

RedNet Control 1.8 Download 

  • RedNet Control 1.8 Supports:
    • Mac:
      • OS X 10.8.x (Mountain Lion) ONLY

Important notes

  • RedNet AM2: When changing attenuation levels in software, please remove headphones and turn the headphone level down. 
  • The RedNet PCIe driver is only compatible with the latest firmware.
  • It is important to note that installing new firmware on to any RedNet Unit can take some time, please DO NOT turn the unit off or interrupt the firmware installation - Units will be unresponsive  during this process.
  • During firmware updates, DO NOT add or remove devices on your Dante network.

 Known Issues

  • RedNet AM2: When a signal is present on Channel 2 and not on Channel 1, RedNet Control will not show signal metering on Channel 2.
  • Mac Only: RedNet Control cannot do two consecutive firmware updates. After the first run of firmware updates, please shut down RedNet Control and reopen to upgrade firmware on second wave of units.
  • Defaults message from Pro Tools does not clear linked channels on RedNet 4.
  • It's possible for RedNet Control GUI to display values of 1–7dB for RedNet 4 when controlled via SysEx. The gain on the unit will still be 0dB or 8dB.
  • During installation, a dialog can appear from Audinate's "Dante Control and Monitoring Installer" about firewall settings on Windows 8. Please manually confirm your firewall settings allow Dante Control & Monitoring through the firewall.
  • When renaming a unit in Dante Controller, RedNet Control will not show this until it has been rebooted.
  • Windows Only: Long device & channel names in RedNet Control will overflow the text boxes.
  • Windows Only: MIDI settings will only be stored between sessions if running with elevated privileges. 

 

 

 

RedNet 3.4 to 3.7 Firmware Update - Rednet 1-5 Only
15/05/2016
Click here for more details:

Rednet 1-5 Brooklyn 1 devices only

For use before installation of Rednet Control 1.8.2 & 1.9.2.

 

Important information: RedNet 1, 2, 3, 4 and 5 devices which are currently running Dante software version 3.4.x are not discovered in RedNet Control 1.8 or 1.9. These devices must be updated to Dante software version 3.7 first. 

 

Your devices will be running Dante software 3.4.x if you have not updated beyond RedNet Control 1.4 (released Q1 2015), or if you have recently purchased devices. To verify this, open Dante Controller, double click on a device to open device view, then select “Status”. In the Dante Information box there will be a number beside “Software Version”. If this reads 3.4.x you will need to proceed with the update procedure below.

 

Please download the zip file below and follow the included instructions to perform this update.

User Guides

RedNet 2 Architect Spec
16/03/2015
RedNet Installation Guide 1.1
24/01/2014
RedNet Brochure
08/05/2013
RedNet 2 User Guide 1.0
21/12/2012
Click here for more details:

This user guide covers the installation and operation of RedNet 2.

RedNet System User Guide 1.0
21/12/2012
Click here for more details:

This user guide covers the main elements of the RedNet Digital Audio Networking system.