RedNet Events and Consultation

Specifications

RedNet_3_Rear

Connectivity

• ADAT Optical inputs 1 – 8 via TOSLINK optical connectors: Each connector supports 8 channels at 44.1 or 48k, 4 channels at 96k (S-MUX2), and 2 channels at 192kHz (S-MUX4)*
• ADAT Optical outputs 1 – 8 via TOSLINK optical connectors: Each connector supports 8 channels at 44.1 or 48k, 4 channels at 96k (S-MUX2), and 2 channels at 192kHz (S-MUX4)*
• AES/EBU inputs and outputs 1 – 8 via DB25 connector (replaces port one of the ADAT inputs when in use)
• S/PDIF input 1 – 2 via coaxial port (replaces one AES bank when in use)
• S/PDIF output 1 – 2 via coaxial port
• Word Clock input via BNC port
• Word Clock output via BNC port
• Dante Ethernet port

* When running at 44.1 or 48kHz, ADAT input ports 5 – 8 are disabled and ADAT output ports 5-8 mirror output ports 1-4

Inputs

AES/EBU inputs

8 channels, with switchable SRC

AES/EBU connector

25-way female Dsub, wired to AES 59 (combined I/O)

ADAT inputs

32 channels @ 44.1 / 48 / 88.2 / 96 kHz sample rate; 16 channels @ 192 kHz

ADAT connectors

TOSLINK lightguides x 8

S/PDIF input

2 channels, with switchable SRC 44.1 to 192 kHz

S/PDIF connector

Phono (RCA) socket

AES/EBU Input Sampe Rate Converters

Input sample rate range

32 to 216 kHz

Gain error

-0.3 dB

Dynamic Range

> 138 dB (-60 dBFS method)

THD+N

< -130 dB (0.00003%); 0 dBFS input

Outputs

AES/EBU outputs

8 channels, sync-locked to RedNet system sample rate

AES/EBU connector

See “Inputs”

ADAT outputs

32 channels @ 44.1 / 48 / 88.2 / 96 kHz sample rate; 16 channels @ 192 kHz

ADAT connectors

TOSLINK lightguides x 8

S/PDIF output

2 channels, sync-locked to RedNet system sample rate

S/PDIF connector

Phono (RCA) socket

Operating Modes

AES/EBU mode

AES/EBU inputs – Chs. 1 to 8; ADAT inputs – Chs. 9 to 32*; AES/EBU outputs – Chs. 1 to 8; ADAT outputs – Chs. 1 to 32*

ADAT mode

ADAT inputs – Chs. 1 to 32*; AES/EBU outputs – Chs. 1 to 8; ADAT outputs – Chs. 1 to 32*

Digital Performance

Supported sample rates

44.1 / 48 / 88.2 / 96 / 192 kHz

Clock sources

Local or from network master device

Local clock sources

Internal, Word Clock input, AES input 1, ADAT input 1, S/PDIF input

External word clock range

Sample rate ±7.5%

Power

PSU

Internal, 100 - 240 V, consumption 30 VA